      Autonics' first digital remote I/O - ARD series, one of the most cost effective & advanced solutions for DeviceNet based industrial networking tools, supports excellent extensibility and perfect compatibility that covers 4 types of communication; in addition, the series includes various functions - auto communication speed identification, network voltage monitoring and status Flag monitoring functions. ARD series also provides the most effective networking solutions by reducing maintenance cost and working time with simple wiring, high reliability and superior noise resistance.

      Major Features
      * Max. 63 basic modules extensible for each master unit
      * Extended I/O module extension available
       - Max. 3 extended module extensible for each basic module
       - Max. 64 points I/O control available (16 points / module x 4)
      * Supporting various I/O modules & easy maintenance and real-time monitoring possible with;
       - Auto communication speed recognition : automatically identified communication speed when connecting to master unit
       - Network voltage monitoring : Max, Min, current network voltage check / monitoring network voltage setting possible
       - Single byte I/O : 1 byte unit I/O for basic / extended modules
       - Multi byte I/O : multiple I/O possible up to the number of basic/extended modules
       - Extended module counting and Spec reading
       - Connector model type reading : basic / extended module model type reading
       - Status flag monitoring : Status flag monitoring when network voltage is lower than SV

      Specification Table

      Application Fields
      Applicable to semi conductor chip facilities, small machinery and vision facilities for magnifying position control

      Applications Sample

      Ordering Information

      Model list

      Dimensions

      Connections

      User's Guide

      1. Each address of modules should be different and apply power after setting address without applying power to master or, it may cause communicational error.
      2. Do not connect the expansion module after applying power or, it cannot recognize the expansion module.
      3. Communication speed is set in master and OFF the power and apply power again after changing communication speed in master to change the speed during the operation.
      4. Use the rated cable, tap and terminating resistance in module or, it may cause a communicational error.
      5. Use the rated communication cable and examine the disconnection or short circuit before the installation.
      6. Use terminating resistance on both ends of the main line.
      7. Do not use this unit in place with too much dust or serious corrosion problem.
       
      * It may cause malfunction if above instructions are not followed.

      Caution For Your Safety

      * Please keep these instructions and review them before using unit.
      * Please observe the cautions that follow;
      ! Warning : Serious injury may result if instructions are not followed.
      ! Caution : Product may be damaged, or injury may result if instructions are not followed.
      * The following is an explanation of the symbols used in the operation manual.
      ! caution : Injury or danger may occur under special conditions.

      ! Warning
      1. If this unit is used to control machineries (Medical equipment, vehicle, train, airplane, combustion apparatus, entertainment, processing and transportation equipment, elevator and various safety device etc.) enabling to effect on human or property, it is required to install fail-safe device. It may cause a fire, serious human injury and damage on property.

      ! Caution
      1. It should be protected from water or oil.
          It may cause damage or miscontrol due to malfunction.
      2. Please observe the voltage range.
          It may shorten the life cycle or damage to the product.
      3. Please check the polarity of power and wrong wiring.
          It may result in damage to this unit.
      4. Do not short circuit the load.
          It may result in damage to this unit.

       

      會員登錄

      ×

      請輸入賬號

      請輸入密碼

      =

      請輸驗證碼

      收藏該商鋪

      X
      該信息已收藏!
      標簽:
      保存成功

      (空格分隔,最多3個,單個標簽最多10個字符)

      常用:

      提示

      X
      您的留言已提交成功!我們將在第一時間回復您~
      在線留言